Accuracy Of Fluid Measurement: ±0.2~0.5% Medium Temperature: -50℃~200℃
Working Pressure: 0~4.0MPa Relative Humidity: ≤95%
Port: Shanghai Or Other

KMF-Series Coriolis  Mass Air Flow Meter 0

Vectra Mass Air Flow Meter Product advantage

1) Using the world's most advanced second generation transmitter technology - DSP technology, higher precision, wider range, more simple structure, more stable operation.

2) Measurement of high pressure gas (such as CNG compressed natural gas (LNG), low temperature liquids such as liquefied natural gas, liquid nitrogen).

3) Using high-precision processing technology, ensure the sensor quality, zero stability.

4) Using digital signal processing (DSP) technology, metering system host through the 485

communication, the relevant parameters, to obtain the required such as: mass flow, volume flow rate,temperature, density, the state information.

5)Through the debugging software or manual debugging device can read the fault code, solving the problem of inconvenient meter using the staff more comprehensive, troubleshooting

6)Support the standard industrial control communication protocol ModbusRTU, easy configuration and use.

7) According to user needs, mass flowmeter in design and manufacture of special specifications and has special function, tailored to the user.

Vectra Mass Air Flow Meter Measuring principle

1) The principle of measuring flow based on rule of Coriolis Motion.

2) After transmitter connecting with sensor, time difference was measured by signal of velocity sensor, then calculate mass flow value by mass circulation calibration coefficient.

3) Transmitter is used to make stream tube resonant, measure mass and density parameters .etc according resonance frequency.

KMF-Series Coriolis  Mass Air Flow Meter 1

KMF-Series Coriolis  Mass Air Flow Meter 2

 

Dimensions of large - scale instrument

 

 

 

Model

Weld Neck Flanges-ANSI B16.5

 

 

A

 

 

B

 

 

C

 

 

E

 

 

F

 

 

W

 

 

G

 

 

K

 

 

d

 

 

D

DN

LB

KMF-1-6c

100

150

670

510

740

858

1092

260

19.1

190.5

157.2

228.6

KMF-1-6CD

125

150

670

510

740

858

1092

260

22.4

215.9

185.7

254

KMF-1-6D

150

150

860

670

950

1130

1370

280

22.4

241.3

215.9

279.4

 

KMF-Series Coriolis  Mass Air Flow Meter 3

 

KMF-Series Coriolis  Mass Air Flow Meter 4

KMF-Series Coriolis  Mass Air Flow Meter 5

KMF-Series Coriolis  Mass Air Flow Meter 6

 

KMF-Series Coriolis  Mass Air Flow Meter 7

KMF-Series Coriolis  Mass Air Flow Meter 8

 

Applied Range

KMF-Series Coriolis  Mass Air Flow Meter 9

KMF-Series Coriolis  Mass Air Flow Meter 10

 

Company Show

KMF-Series Coriolis  Mass Air Flow Meter 11

KMF-Series Coriolis  Mass Air Flow Meter 12

KMF-Series Coriolis  Mass Air Flow Meter 13

 

 

FAQ

1.Q: Why choosing vectra mass air flow meter but not the other flow meters?

A: vectra mass air flow meter has huge difference with the volumetric flow meters.

All the other flow meters except the Coriolis mass flow meters could be called as volumetric flow meters, including, turbine flow meters, thermal mass flow meters, vortex flow meters, electromagnetic flow meters, etc.

For the vectra mass air flow meter:

The measurement of the vectra mass air flow meter will NOT be influenced by the factors of temperature, pressure, density, viscosity, etc. And the compensation calculation is NOT required.

The accuracy of the Coriolis Mass Flow Meters is ±0.1%, ±0.2% . The accuracy will NOT be influenced by the factors mentioned above.

Compared to this,

For the Volumetric Flow Meters:  

The measurement of the volumetric flow meters WILL BE influenced by the factors of temperature, pressure, density, viscosity, etc. And the compensation calculation IS REQUIRED.

The accuracy of the volumetric flow meters  is said to be reached by ±0.5%. While, the actual accuracy is hard to reach this level of ±1%. The accuracy will be influenced by factors as mentioned above.

 

 

Company Information

KMF-Series Coriolis  Mass Air Flow Meter 14

 

Xi'an Kacise is certified by ISO 9001-2008, GJB 9001B-2009, CE, intrinsic safety explosion-proof and isolated safety explosion-proof, etc. which assure our products are conform to the international standards.

We have been specializing in manufacturing pressure, level and flow measuring instruments and related products for 10 years. We have experienced technical and management personnel, through the efforts of our entire staff, we have become a professional measuring instrument manufacturer and solution provider. And we are continuously trying to improve product quality.

Currently, Kacise sensor is already exported to America, Spain, Australia, Chile and 20 other countries and regions, and received many favorable feedbacks. Our overseas distributers are also increasing. We regards “reasonable prices, efficient production time and good after-sales service” as our tenet, and hope to cooperate with more customers for mutual development.

 

 

Contact Details
Xi'an Kacise Optronics Co.,Ltd.

Contact Person: Ms. Evelyn Wang

Tel: +86 17719566736

Fax: 86--17719566736

Send your inquiry directly to us (0 / 3000)

Contact

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Factory Address:i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.